scxi-1162hv. 1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properly. scxi-1162hv

 
1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properlyscxi-1162hv Supported Operating Systems

Industries. This module is controlled by the DAQ device serially in multiplexed-mode over the SCXIbus making it easy to integrate multiple modules into existing SCXI systems without additional DAQ devices or cabling. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. 6: Windows 10/8. Application Software 1 Versions Supported by NI-DAQmx 18. 1. All Manuals. 1 /7 SP1 (32ビットおよび64ビット. This warranty includes parts and labor. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Product: SCXI-1162HV Product type: Modular instrument/data collection product Express delivery: Please consult customer service Application scope: transportation, aerospace, industrial machinery. 3 min read. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. 0. These relays are suitable for switching, routing, and controlling medium-level signals. The. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. SCXI-1162HV SCXI1162HV: 5998-01-567-9476: Circuit Card Assembly: End Item Identification: Mobile engine test system (mets) 4920-99-284-3113, T56-A-15 (engine C-130) Special Features: 32 ch high-voltage isolated digital input module: 64667SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. Welcome to J316Gallery. 1 addresses issues with NI-XNET modules on Ethernet and wireless CompactDAQ chassis not loading properly. The terminal block has 48 screw terminals for easy signal connections. The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. 32-Channel, Input (TTL/CMOS), Digital I/O Module for SCXI —The SCXI‑1162 is an optically isolated digital input module for SCXI. . PXI-6529: 48. . 32-Channel, Input (240 V), Digital I/O Module for SCXI. 2. . The optical isolation of the SCXI‑1162HV eliminates ground. DAQ Traditional NI-DAQ TM User Manual Version 7. 32-Channel, Input (240 V), Digital I/O Module for SCXI. Windows Embedded Standard 7 、SP1(CompactDAQコントローラ上). We are using PXI 6229 as communicating card. Re: PXIe-6361 does not recognize SCXI modules on SCXI-1000. NI-DAQmx 17. Supported Operating Systems. The terminal block has 48 screw terminals for easy signal connections. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. SCXI™ Getting Started with SCXI. If you are using NI-DAQmx with a USB DAQ device on Windows XP, you should install the Microsoft hotfix reported in Microsoft Knowledge Base 969238. SCXI™ Getting Started with SCXI. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. com ¥ ni. SCXI-1162HV User Manual - National Instruments. The official life cycle status of the NI SCXI-1162HV has been stated as “Obsolete” according to National Instruments. 6. NI-DAQmx 15. NI-DAQmx Readme Updates. Find many great new & used options and get the best deals for National instruments NI SCXI-1162HV 182638E-01 SHIP at the best online prices at eBay! Free shipping for many products!NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;The SCXI-1000 chassis is capable of holding up to four modules while the SCXI-1001 can hold up to 12. 1 para WinXP. The SCXI-1162HV User Manual is organized as follows: • Chapter 1, Introduction, describes the SCXI-1162HV; lists what you need to get started with your SCXI-1162HV; describes the software programming choices and optional equipment; and explains how to unpack the SCXI-1162HV kit. SCXI-1321 Terminal Block. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. The following operating systems are supported in NI-DAQmx 14. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. 32-channel isolated ac/dc digital input module (43 pages) I/O Systems National Instruments SCXI-1102 Calibration Procedure. Wechat:17750010683. I know that both 11. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. 1 1 /7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI software installs. 1 1 /7 SP1 2 (32-bit and 64-bit) Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers) Windows Server 2012 R2 1 (64-bit) Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role) 1 NI software installs VC2015 Runtime and . English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. com. The terminals labeled GND are not used on the SCXI-1162. --. 8-Channel, General-Purpose Switch Module for SCXI —The SCXI‑1161 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. EN. 18 MB. Windows 10 (32비트 및 64비트) Windows 8. We have a great online selection at the lowest prices with Fast & Free shipping on many items!SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01NI工程師你好,我想問一下關於OVDER TRACKING的一些相關的東西 我是初學者有沒有一些範例能參考看看。我們是用LABVIEW7. Logiciels d'application supportés. ni scxi-1600 usb模块 重要通知:用于USB DAQ设备和Windows XP的Microsoft修补程序 如在Windows XP平台上使用USB DAQ设备和NI-DAQmx,建议安装 Microsoft知识库文章969238 中的Microsoft修补程序。You are using an SCXI-1530, SCXI-1531, or SCXI-1540 device with accelerometer, linear-voltage differential transformer (LVDT), or rotary variable-differential transformer (RVDT) virtual channels, which are not supported by NI-DAQmx. SCXI-1162HV. Whats app:+86 17750010683. Chapter 4, Theory of Operation, contains a functional overview of the SCXI-1122 module and explains the operation of each functional unit making up the. The SCXI‑1162HV. 531X304IBDAMG1 F31X304IBDAMG1–00609. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. The output voltages of this module are multiplexed onto a single channel of a data acquisition device. The National Instruments SCXI-1326 is designed for high-voltage digital input or digital output applications. The neutral is connected to the GND terminal for the bank, and the inputs go to the first thre. This warranty includes parts and labor. SCXI-1540 using Measurement & Automation Explorer or through function calls to NI-DAQ. 0 para Win95. Application Software 1 Versions Supported by NI-DAQmx 18. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. Ideal for medium-power automated test loads, the SCXI-1169 offers maximum relay density and is fully software-programmable, with a 32. SCXI-1162HV ; Isolated output ; SCXI-1163 ; 28 National Instruments Products. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. This module is controlled by the DAQ device serially in multiplexed-mode over the SCXIbus making it easy to integrate multiple modules into existing SCXI systems without additional DAQ devices or cabling. SCXI-1162HV PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, INPUT MODULE, DIGITAL 32 CHANNEL, HIGH VOLTAGE ISOLATED, 240 VAC/DC, DIGITAL, PROGRAMMED BY THE DAQ DEVICE SERIALLY OVER THE SCXIBUS The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. The National Instruments TBX-1326 is a high-voltage terminal block with 48 screw terminals for the SCXI-1162 Series and SCXI-1163 Series modules. Warning: The TBX-1326 and SH48-48-B limit the maximum working common-mode voltage between banks or between banks and earth ground to 250 V rms maximum. The neutral is at earth ground potential. 1支持下列操作系统: Windows 10(32位和64位) Windows 8. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The best choice for this health monitoring system was a combination PXI/SCXI chassis due to its compactness and high density of instrumentation. Mobile/ WeChat/ WhatsApp:+86 13365909307. com or CALL 800 813 3693 (U. Part Number: 183087H-03, 183087K-03L, 183087G-03, 183087F-03. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01ni scxi-1600 usbモジュール 重要なお知らせ: USB DAQデバイスおよびWindows XP用Microsoft Hotfix Windows XPにNI-DAQmxをインストールしてUSB DAQデバイスを使用する場合は、 技術サポートデータベース(969238) に記載されているMicrosoft Hotfixをインストールすることをお勧めし. 1 fixes an upconversion issue for DSA timebases on the NI 9469 and a counter input properties issue on the NI 9361. EN. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. HMCS. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory ABB…NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;DAQ NI-DAQ™ User Manual for PC Compatibles Version 6. Product Name: SCXI-1162HV Module Product Description: The SCXI-1162HV module is a high-voltage multiplexer module designed for use with the SCXI platform. NI DAQCard-6024E 200 kS/s, 12-bit, 16 AI channel, two AO channel, 8 DIO line, two counter/timer device;. SCXI Terminal Blocks 3 BUY ONLINE at ni. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. 18 MB. The optical isolation of the SCXI-1162 and SCXI-1162HV eliminates ground-loop problems and isolates the host computer from damaging voltages. Explore una extensa variedad de contenido de soporte, incluyendo ejemplos e información para solución de problemas. EN. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. Windows Server 2008 R2 P1(64ビット、サーバコアロールでは. . The. --. SCXI-1321 Terminal Block. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B Ð High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32-A Sockets for current. QQ: 3221366881. National Instruments will, at its option, repair or SCXI-1162HV PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, INPUT MODULE, DIGITAL 32 CHANNEL, HIGH VOLTAGE ISOLATED, 240 VAC/DC, DIGITAL, PROGRAMMED BY THE DAQ DEVICE SERIALLY OVER THE SCXIBUS The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. 5 adds support for LabVIEW NXG 2. The terminals labeled GND are not used on the SCXI-1162. Unfortunately, you cannot use your PXIe-6361 and SCXI-1162HV in parallel mode. Windows Server 2008 R2 P1(64ビット、サーバコアロールでは. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. We have 2 National Instruments SCXI-1162HV manuals available for free PDF download: Getting Started, User Manual National Instruments SCXI-1162HV Getting Started (158. Call. The TBX-1326 is a DIN-rail mountable terminal block that connects to an SCXI module front connector with an SH48-48-B cable. National Instruments SCXI-1162HV 32-Channel Isolated Digital Input ModuleThis unit ships sealed in the original manufacturer's static bag. There are two other modules in the SCXI chassis which aren't being used yet; a SCXI-1162HV and SCXI-1163-R. 531X304IBDASG1 F31X304IBDAMG1–00609. SCXI-1162HV User Manual - National Instruments. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. SCXI-1162HV, 32-Channel, Isolated AC/DC, Digital Input Module Get Quote SCXI-1163. . The 16 DC outputs were controlled with an SCXI-1163R. SCXI modules controlled the stand. 07-16-2018 11:58 AM. For High-Voltage Digital Input or Digital Output Applications. 00. SCXI-1162HV: 32. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. Victoria is the capital city of the Canadian province of British Columbia, on the southern tip of Vancouver Island off Canada's Pacific coast. EN. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. SCXI-1162HV User Manual - National Instruments. 1 No connects appear on pins 20 through 22 of devices that do not support AO or use an external reference. The NI SCXI-1162 (Part Number: 776572-62) is an optically isolated Digital Input Module, which can interface to field digital logic signals where common-mode voltages may exist, such as TTL and CMOS. National Instruments will, at its option, repair or National Instruments SCXI terminal blocks provide a convenient. EN. Voltage Input Module for SCXI. Important Information Warranty Your DAQ hardware is warranted against defects in materials and workmanship for a period of one year from the dateThe following operating systems are supported by NI-DAQmx 17. 1: Windows 10/8. NET 4. . I am trying to wire an SCXI-1162HV module and I want to make sure it can handle my input. 6. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. com. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory ABB…Starting in NI-DAQmx 8. The terminal block has 48 screw terminals for easy signal connections. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. 1 para WinXP. Extended I/O Connector. . 5; LabVIEW: 2015, 2016, 2017, and 2018: LabVIEW Real-Time Module: 2015, 2016, 2017, and 2018: LabVIEW NXGSCXI-1162HV Controller module, NI, SCXI-1162HV Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. The vessel (max capacity 5200 passengers plus 1730 crew) was scheduled for an inaugural visit to Victoria BC on June 8, 2018. The terminals labeled GND are not used on the SCXI-1162. Add to Quote. Features: 48-Screw Terminals for Signal Connections. National Instruments SCXI-1162HV User Manual (43 pages) 32-Channel Isolated AC/DC Digital Input Module. 2016年起NI-DAQmx将不再支持Microsoft Windows Vista、Windows XP和Windows Server 2003. The SCXI-1162HV is designed for 240 VAC/VDC input. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-0132-Channel, Input (240 V), Digital I/O Module for SCXI. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Website: GE General Electric. 1 Readme. PFI 0. 5. I use the digital data logger to log the input from lines 4 and 7 and the digital da. All terminals of the NI TBX-1326 are used when it is coupled with the SCXI-1163. The NI SCXI-1162HV features 32 Channels and an Input Current Limiting of 1 mA. discontinued by manufacturer, terminal block, feed through, 777687-02. NI SCXI-1600 USB module; Important Notice: Microsoft Hotfix for USB DAQ Devices and Windows XP. This file contains important information about NI-DAQmx, including installation instructions and known issues. One of the 1162HV is the communication module between the pci card and the rack. Quarter-Bridge Configurations. Ships in 5-10 Days. This guide describes how to use and install the SCXI-1326 high-voltage terminal block with the SCXI-1162, the SCXI-1163, the SCXI-1162HV, and the SCXI-1163R modules. Website: GE General Electric. You can, therefore, easily integrate SCXI‑1162HV modules into existing SCXI systems without additional DAQ devices or cabling. NI-DAQmx 16. SCXI-1162HV User Manual - National Instruments. . Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. . 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. CTR 0 GATE. NI-DAQmx 17. 如果连接到dio板卡,设置跳线 w2 到 dio 位置SCXI-1353 Shielded Cable Assembly 2 ni. com. NI-DAQmx 17. La aplicación usaba la función WriteToDigitalLine() con el archivo de configuración. 1 1 (32位和64位); Windows 7 SP1 2 (32位和64位); Windows Embedded Standard 7 2 、SP1(32位和64位); Windows Server 2012 R2 1 (64位); Windows Server 2008 R2 1 、SP1(64位,不支持Server Core Role); 1 NI软件安装VC2015运行引擎和. According to the the SCXI-1162HV User Manual "Only DIO DAQ boards can read the data from the SCXI-1162HV in parallel mode; MIO boards can only read from the SCXI. NI SCXI-1600 USB module; Important Notice: Microsoft Hotfix for USB DAQ Devices and Windows XP. 1 1 (32-bit and 64-bit); Windows 7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2, SP1 (32-bit and 64-bit); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on. NI-DAQmx 15. National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (512) 418-1111 Branch Offices: Australia 03 9 879ni scxi-1600 usb 모듈 중요한 알림 사항: USB DAQ 디바이스 및 Windows XP를 위한 Microsoft Hotfix Windows XP에서 USB DAQ 디바이스와 함께 NI-DAQmx를 사용하는 경우, Microsoft Knowledge Base 969238 의 설명과 같이. Return to Home Page; Toggle navigation; Solutions. Set the voltage selection tumbler to the correct voltage for your. 32-Channel, Input (240 V), Digital I/O Module for SCXI —The SCXI‑1162HV is an optically isolated digital input module for SCXI. SCXI-1127. (SSK 876) HMCS Victoria is a long-range hunter-killer (SSK) submarine of the Royal Canadian Navy, the lead ship of her class. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01 The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. 6. SCXI-1162HV. ni scxi-1600 usb 모듈 중요한 알림 사항: USB DAQ 디바이스 및 Windows XP를 위한 Microsoft Hotfix Windows XP에서 USB DAQ 디바이스와 함께 NI-DAQmx를 사용하는 경우, Microsoft Knowledge Base 969238 의 설명과 같이. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory ABB…本文件包含NI-DAQmx的重要信息,包括安装指南和已知问题。. NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R switch module; NI SCXI-1520 strain gage input module;The RT system consists of the PXI-8140RT, a PXI-6259 M-series controlling a SCXI chassis, and the SCXI-1102B and SCXI-1581 pair capable of measuring 32 RTD's. It has isolated input channels with 300 Vrms working isolation as well 12 programmable gain settings. NI SCXI-1141, SCXI-1142, and SCXI-1143 lowpass filter modules ; NI SCXI-1160 16-SPDT general-purpose relay module; NI SCXI-1161 8-SPDT power relay module; NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module 100-Channel, General-Purpose Switch Module for SCXI —The SCXI‑1169 is a general-purpose switching module with independent single‑pole single‑throw (SPST), also called Form A, armature relays. Contents. SCXI-1102C, SCXI-1124, SCXI-1162HV modules TC-2095, TBX-1303, TBX-1325, TBX-1326 terminal blocks. The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. The PXI-1052 is a combination PXI and SCXI chassis with 4 PXI slots and 8 SCXI slots. SCXI-1162HV User Manual - National Instruments. 1. National Instruments SCXI-1162HV User Manual (43 pages) 32-Channel Isolated AC/DC Digital Input Module. SCXI-1162HV. One of the 1162HV is the communication module between the pci card and the rack. 1 also fixes issues with PXIe-4303 and PXIe-4339 devices showing incorrect data when changing the. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. SCXI-1162HV User Manual - National Instruments. 3. . The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. The following figures show the pin assignments of the two 68-pin connectors. Janvier 2019. Read this document to learn how to use NI. " SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01 With the SCXI-1162HV less than 1VAC is guaranteed to be a 0 and greater than 10VAC is guaranteed to be a 1. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. The following operating systems are supported by NI-DAQmx 17. 5: Windows Vista Business edition, Service Pack (SP) 1 or greater (32-bit and 64-bit) Windows Server 2008 R2, SP1 or greater (64-bit, not supported on Server Core Role) Note Support for Windows Server 2003 R2 may require disabling physical address extensions. Digital SCXI Modules In addition to analog SCXI modules, National Instruments produces a variety of digital modules—the SCXI-1160, SCXI-1161, SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. Quarter-Bridge Configurations. The other four were input with an SCXI-1121 to allow an input that required excitation. 0; LabVIEW: 2016, 2017, 2018, and 2019: LabVIEW Real-Time Module: 2016, 2017, 2018, and 2019: LabVIEW NXGSCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. 2를 설치합니다. . English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. 4-10 Figure 4-5. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. SCXI-1162HV NI module, NI, SCXI-1162HV NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import. Each SCXI chassis contains an 1162HV module for reading high voltage digital signals and an 1102 thermocouple module connected to a 6251 M Series MIO DAQ card to read up to 32. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. I have seawrched many discussion forums, the examples and tutorials, and cannot find much on setting up and using the SCXI-1162HV 32-Channel. 01 and NI. Getting Started with SCXI - National Instruments. I know the inputs are tied together. SCXI-1321 Terminal Block. 1 1 /7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI software installs. For example, you can use an SCXI. . 32-Channel, Input (TTL/CMOS), Digital I/O Module for SCXI —The SCXI‑1162 is an optically isolated digital input module for SCXI. com. EN. Product Security and Critical Updates. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01 SCXI-1162HV User Manual - National Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский български العربية Unknown This question has to do with SCXI-1162HV, DAQmx, and Digital Signal Acquisition, but I do this programming in CVI 2010 using the SCXI-1600 USB Digitizer and DAQmx, so I'll start here. Configuration système requise. The SCXI-1162 and SCXI-1162HV are controlled by the DAQ deviceSCXI ™-1162HV+ Figure 1 System Health Probability Screen The Challenge: The National Defense Budget continues to diminish. SCXI-1305 Terminal Block Figure 1. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. It allows for switching and routing of high-voltage signals, making it suitable for a wide range of applications in industrial automation and control systems. Categories: NI. 32-Channel, ±10 V, 10 kHz Filter, Voltage Input Module for SCXI —The SCXI‑1102C is designed for the signal conditioning of thermocouple, millivolt, volt, and current signals. . com 100-pin E Series DAQ device Two SCXI modules Note Refer to the Connections and Pin Assignments section for the SCXI modules that you can use with each 100-pin E Series DAQ device. The NI SCXI-1162HV contains 32 channels. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. Digital Input Number of channels. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. scxi-1302. NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R switch module; NI SCXI-1190 and SCXI-1191. Between those two values is undefined. Windows 8. 关于本版本NI-DAQmx自述文件的更新内容,请访问. If you are using NI-DAQmx with a USB DAQ device on Windows XP, you should install the Microsoft hotfix reported in Microsoft Knowledge Base 969238. . National Instruments SCXI-1162- TTL/CMOS: Call: SCXI-1162HV: National Instruments SCXI-1162HV- 240 V: In Stock Ships Today: SCXI-1163: National. 4-12 . In this case, the Vcc terminal is used for power supply, the GND terminal is used as the ground, and the CH(X. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. 531X304IBDARG1 F31X304IBDAMG1–00609. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. NI-DAQmx 16. Default Pin Number. com. 5. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. arinc & 1553 . SCXI-1162HV User Manual - National Instruments. Systèmes d'exploitation supportés. NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory ABB…connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. The terminal block has 48 screw terminals for easy signal connections. Supported Operating Systems. NI-DAQmx自述文件更新. EN. ¥ 668. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01I/O Systems National Instruments SCXI-1162HV User Manual. It sounds like your 1162HV is working correctly. 0 Data Acquisition Software for the PC Traditional NI-DAQ User Manual April 2003 Edition Part Number 370696A-01. SKU: SCXI-1162HV. The following operating systems are supported by NI-DAQmx 17. 0: Windows 10/8. 1 1 /7 SP1 2 (32-bit and 64-bit 3); Windows Embedded Standard 7 2, SP1 (on Compact DAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on Server Core Role); 1 NI. for any updates to the current NI-DAQmx readme. Academic and Research; Aerospace, Defense, and Government;. Power off both the PXI and SCXI power switches, and unplug the chassis. The SCXI-1162HV is designed for 240 VAC/VDC input signals. NI DAQCard 6024E 200 kS/s, 12-bit, 16 AI channel, two AO channel, 8 DIO line, two counter/timer device. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. This chapter also includes specifications and connection instructions for the signals on the SCXI-1122 connectors. SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module, NI, SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module The NI SCXI-1162HV (Part Number: 776572-62H) has 32 channels of optically-isolated digital inputs, which are organized into eight separate banks of four input lines each. The SCXI-1162HV Digital I/O Module can monitor TTL level inputs and sense the existence of high-voltage AC and DC signals. All prices are shown in USD. The following operating systems are supported in NI-DAQmx 16. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Hello, Trying to keep it short, we are trying to get Labview 5. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Spare parts experts in the field of industrial automation. NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;scxi-1581は、一般的にscxi-1102とともに使用して、多数チャンネルrtd計測に対応します。 SCXI-1581はこれらの計測の励起ソースとして使用されましたが、PXIおよびCシリーズでの推奨代替品では、励起ソースと計測機能の両方がデバイスに組み込まれています。SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. info and type rdfis5 to order a configured PXI/SCXI combination chassis. It interfaces to field digital logic signals, such as TTL and CMOS, in which high-common-mode voltages can be present. NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and SCXI-1531 modules for accelerometers and microphones; NI SCXI-1540 linear variable differential transformers (LVDT) module;I have an application that could use 4 SCXI 1162 HV modules. SCXI-1162HV User Manual - National Instruments. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. FIM card MOOG — D136-001-007 Servo valve, controller, module NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module,. NI-DAQmx 16. Website: GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK. NI-DAQmx 16. The SCXI-1162HV works with National. The first input I know will work I have Gnd on Gnd and 28V on The input. Well, my question is how i can control this scxi 1001 device. The SCXI-1162HV can monitor TTL level inputs as well as sense the presence of high-voltage AC and DC signals. Recursos para Soporte del Producto. NI-DAQmx 15. SCXI-1162HV User Manual - National Instruments. I use the digital data logger to log the input from lines 4 and 7 and the digital da. The SCXI 1162HV has 32 channels of optically—isolated digital inputs, arranged into eight isolated banks of four input lines each. The following operating systems are supported by NI-DAQmx 17. Windows 10/8. Überblick. I've configured with MAX two channels the first is the channel to Dev1 port PA0, teh second is the channel to Dev1_SC1_MD1 DIN1. 1. +5 to +10 V Digital Logic Levels for the SCXI-1162 Digital logic levels for the SCXI-1162HVWith the SCXI-1162HV, the Vcc terminal remain unused, the GND terminal is used for ground reference, and the CH(X) terminal is used for the input signal. 4-10 Figure 4-5. NI-DAQmxは、NIデータ収集(DAQ)デバイスとの通信と制御を行うために使用するソフトウェアです。. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. Add to Cart. National Instruments SCXI-1162HV 32-Channel Isolated Digital Input Module Part Number: 182638-01, 182638C-01, 182638E-01, 185628C-01, 182628E-01, 182638D-01 . The TBX-1326 has 48 screw terminals arranged in eight. About This Manual. E-mail: [email protected]: Windows 10/8. 1 Readme. TBX-1326 SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B Ð High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32. The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. The TBX-1326 is a DIN-rail mountable terminal block that connects to an SCXI module front connector with an SH48-48-B cable. We are currently using a National Instruments DAQ - SCXI-1162HV and our current configuration is PXI. The optical isolation also alienates the host device from damaging voltages. The SCXI-1162HV is a module for sensing the presence of AC or DC voltages where high common-mode voltages may be present. Hi to everyone!, I have a pci-6503 conected to a scxi 1001 device. EN.